1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
HomeHome > Products > Load Bank > 1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank
1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

Overview Product Description 1000KW AC Dummy Air Cooling Resistive Generator Load Test Load Bank >LOAD BANK SPECIFICATIO
Overview
Basic Info.
Model NO. RT1000KWLB
Application Generator/UPS Load Test
Customized Customized
Surface Treatment Powder Coating
Control Mode Manual+Automatic
Frequency 1.0
Design Indoor/Outdoor
Power Capacity 1000kw
Rated Voltage AC400V/415V/Customized
Name Load Bank
Transport Package Film Wrapping/Wooden Box
Specification Reference the specification following
Trademark Rata
Origin China
HS Code 9030899090
Production Capacity 10 Set/Month
Product Description

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

Product Description

1000KW AC Dummy Air Cooling Resistive Generator Load Test Load Bank

>LOAD BANK SPECIFICATION
Nominal voltage: AC400V/415V/CustomizedNominal power: 1000kW Frequency: 50/60HzPower factor: 1.0Min. step: 1kWLoad step: according to customer needsWork power: AC380V/50/60Hz(if the voltage customer supplied lower/higher than the voltage,there will be a trnasformer)Test power connection: copper bar,3 phases 4 wireWork power connection: terminal,3 phase 4 wireControl mode: manually or automaticResistor8020 NiCr alloy finned resistorEach resistance element: insulation impedance DC2000V/10MΩ above Withstand voltage AC2000v for 1 min; Resistance error of each resistance tube: ±2%Can stable work under 350ºC.Cooling systemForced air cooling,horizontal air outlet,horizontal air outletAxial fanAirflow/Fan power and air volume shall be designed according to 2 times surplus coefficient of heat loss. Brand: first-line well-known brand at domestic and abroadPower supply mode: 3phase AC power supply.Noise:≤ 65db (3M)The fan adopts axial flow fan, aviation aluminum fan blade, decentralized air supply design, sufficient air volume, low noise, high strength, corrosion resistance, durability and other advantages of the fan blade .Hot air discharge distance:≥ 3MLoading accuracy: ≤ 3% Three phase balance: unbalance degree: ≤3%Duty cycle: continuous workLoad protection: short circuit,overcurrent,over voltage,high temperature,fan fault protection,loaw air volume,emergency stopInsulation class: FMeasurement accuracy: the display accuracy is 0.5,the sampling accuracy is 0.2Electrical parameter display: three phase voltage,three-phase current,frequency, power,etcVoltage rising mode: realized by transformerLoad expansion: parallel expansion of multiple load bankStandard: meet international standard,ship standard and telecommunication standardTransport: load-bearing lifting hole,castors or forklift hole can be selected.Color: RAL7035 / customizedLoad bank cabinet: Q235 steelAmbient temperature: -20ºC to 50ºCHumidity: up to 100%Altitude: up to 2500mAtmospheric pressure: 86 to 106kPaDimension(L*W*H): 2100*1510*1955mmWeight: 1800kg Detailed Photos

1000kW load bank manual control + outdoor design picture

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank


1000kW load bank automatic control + outdoor design picture
1000kW load bank manually control + indoor design picture

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank


1000kW load bank automatic control + indoor design picturePackaging & Shipping1000kW load bank will be packed with wrapping film+wooden pallet for movement.

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

Other Products
Company Profile

Rata technology was established in 2013 and located at Luojiang High and New Technology Zone, Deyang City, China. The factory is nearby the high way and national road, with convenient shipment. It is about 5 hours from our factory to the nearest port.

There are professional technicians and skilled workers. During past 9 years, we are focus on development and production of kinds of load bank. By far, we have obtained 25 patents of load bank, ISO 9001 certificates and 8 computer software copyrights. We are not only focus on products quality, but also on service. By far we obtained 5 stars contract performance capacity certificate and 7 stars after sales service certificate. Rata Technology mainly produce and sale resistive load bank, resistive inductive combined load bank, resistive inductive and capacitive combined load bank, rack mounted load bank, DC load bank, electrical load bank and battery discharger. Battery discharge test: Power battery, lead acid battery and fuel battery, BMS and battery protection equipment test, test of communication power supply and server power supply. Virtual load test of solar array and industrial motor. Test of DC charging pile, charging module and other electronic power devices. Our load bank have been exported to Europe, Africa, , Asia and other regions and have good reputation. You are welcome to visit our factory and look forward to cooperate with you.Certifications

1000kw AC Dummy Air Cooling Resistive Generator Load Test Load Bank

FAQ

1- Are you manufacturer?
Yes, we are manufacturer of load bank.
2- What is the delivery time?
30-35 days generally.
3- What certificates you have?
ISo9001:2015,ISO14001:2015,ISO45001:2018,CE,SGS
4- Do you accpect customized logo,color?
Yes.
5- What is the nerest port?
Shanghai port,China. Generally we can delivery the goods to any China port.
6- What price you can quote?
EXW,FOB,CIF,DDU
7- What is the payment term?
T/T