Inductive Load Bank 1000kVA Dummy Load Bank AC Load Bank
Product introductionInductive load bank 1000KVA dummy load bank ac load bankMain functions:1. Users can set adjustable l
Basic Info.
Model NO. | inductive load bank 1000KVA |
Load Way | Electronic Load |
Loading Method | Static Load |
Display | Digital |
Control | Computer Control |
Weight | 1000-2000Kg |
Power Source | AC380V |
Oil Cylinder Position | No |
Dimension | About 2440 mm*1400mm*1680mm |
Load Tolerance | 5% |
Color | Variety |
Transport Package | Plywood Cases |
Specification | 1000KVA |
Trademark | triumph load |
Origin | China |
HS Code | 90303390 |
Production Capacity | 100/Month |
Product Description
Product introductionInductive load bank 1000KVA dummy load bank ac load bankMain functions:1. Users can set adjustable load power within rated power.2. Current, voltage, frequency, power factor, and active power, reactive power, and apparent power can be displayed.3. With software programmable control, graphs of current, voltage, frequency, power factor, power can be displayed, saved and printed.Control mode: manual control (control panel) with remote control or PC intelligent control.Display meters: multi-function digital meter or generator tester. Protection: Over load protection, over heat protection, short circuit protection, Emergency stop switch, etcCooling: Force air cooling.Specification
System Parameter | |
Rating voltage/frequency | 400V, 3 phase 4 wire 50Hz |
Max Load Power | Apparent Power: 1000KVA Resistive Load: 800kWInductive Load: 600KVAR |
Load Resolution | Resistive Load: 12 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100k,200kW,200kW,200kW Inductive Load: 11 steps 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,200KVAR,200KVAR |
Power Factor | 0.8(lag) |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
Wire Connection | Load bank input--Copper bar (star coupling "Y")Control power input--Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Max Protection Grade | IP21 |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Fan; horizontal inlet air, horizontal exhaust cooling |
Transportation | Hoisting, there are lifting lug in top of casing |
Color | Grey RAL7035 or as required |
Dimension | About 2units* 2440 mm×1400mm×1680mm(L×W×H)( |
Operating Environment Parameter | |
Workplace | Indoor |
Ambient Temperature | -10ºC~+50ºC |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
certificate
Send to us