Laod Bank AC 3 Phases 2000kw 6.3/10.5kv 50/60Hz Resistive Inductive Load Bank for Genset Generator Testing Shipyard Dummy Load
HomeHome > Products > Inductive Load Bank > Laod Bank AC 3 Phases 2000kw 6.3/10.5kv 50/60Hz Resistive Inductive Load Bank for Genset Generator Testing Shipyard Dummy Load
Laod Bank AC 3 Phases 2000kw 6.3/10.5kv 50/60Hz Resistive Inductive Load Bank for Genset Generator Testing Shipyard Dummy Load

Laod Bank AC 3 Phases 2000kw 6.3/10.5kv 50/60Hz Resistive Inductive Load Bank for Genset Generator Testing Shipyard Dummy Load

Overview Rata resistive inductive load bank is developed on the basis of resistive load bank. Shunt reactor or magnetic
Basic Info.
Model NO. RATA-HRL2000KW/6.3/10.5KV/50/60Hz
Voltage 50/60Hz
Rated Load 2000kw
Application Data Center Generator UPS
Customized Customized
Surface Treatment Chroming
Display Accuracy 0.2
Connection Mode Tn-C
Load Accuracy Plus or Minus 3%
Rated Voltage 6.3/10.5kv
Transport Package Carton/Wooden Case or Customized
Specification 6000*2438*2500
Trademark Rata
Origin China
HS Code 9030899090
Production Capacity 5000
Product Description

Laod Bank AC 3 Phases 2000kw 6.3/10.5kv 50/60Hz Resistive Inductive Load Bank for Genset Generator Testing Shipyard Dummy Load

Overview

Rata resistive inductive load bank is developed on the basis of resistive load bank. Shunt reactor or magnetic valve controllable reactor can be selected for inductive load,and the power factor is 0.8.Resistive inductive load bank has the advantages of simple operation,small volume and convenient transportation. According to the load capacity,it can be used in parallel.Load test has the advantages of high precision, convenient adjustment, no test preparation time, continuous and long-term use and so on.Intelligent test load system of generator set is divided into two parts: load group and control system;The load control of the bank is divided into local control,local control and remote control. In addition,customers can customize various specifications of load banks according to your own needs.
Resistive Inductive Load Bank Application and Features1. What is the load bank used for? Resistive load bank is mainly used for UPS and other AC power supply or generator test detection occasions.Simulating resistive load can test the performance of AC power supply such as generator set and UPS under different loads.The power input adopts the optimized subsection type to meet the needs of different loads.1. Generator set:diesel generator set factory test2. Detection mechanism:load simulation test,power supply test,contactor life test3. Scientific research institute:analog false load,power supply detection,energy consumption resistance4. Emergency power supply:regular test of AC and DC emergency power supply5. Bank hotel:generator regular load test6. Commercial real estate:backup generator test7. Airport: emergency power supply detection

2.Resistive Inductive load bank Main Functions and advantages
1. Load Test: User can load any power within rated power, and test the output capacity of under test power supply.2. The resistive Inductive load bank adopts new power consumption components. The resistance is heat shrinkable and sealed in the stainless steel pipe. 3. The steel pipe is equipped with insulated cooling fins, which has good moisture-proof corrosion performance, good heat dissipation, high insulation performance, safety and reliability.4. The resistance element has high power density, no redness, and an independent cooling fan to ensure the heat dissipation and service life of the whole system.

3. Precautions1. The equipment power cord must be connected correctly.2. Before using the equipment, confirm that the equipment is in normal state, and the insulation to ground of 500V is not less than 1m Ω.3. It is forbidden to use the equipment under abnormal voltage.4. The equipment must be safely and reliably grounded before use.5. There shall be no obstacle 2 meters away from the air inlet and outlet of the equipment to avoid poor heat dissipation of the equipment and failure of the equipment to work normally.6. After high temperature protection, the equipment shall be reset to avoid secondary loading after load cooling7. During the test, pay attention to power safety to avoid electric shock.
Our Service
* 3 years quality warranty.* Supply professional consult and reply technical question in time.* Arrange fast and safe shipment as contract date.* More products' special function please contact the sale manager. You will be replied soon.
Resistive Inductive Load Bank Specification
Resistive Inductive Combined Load Bank Basic Specification
Active power (kW)Inductive power(kvar)Apparent power(kVA)Voltage(kV)P.F.Frequency(Hz)Size(mm,L*W*H)Wt.(Kg)
100075012506.3/10.50.850/603000*2438*25003500
120082513254000*2438*25003900
150090014004000*2438*25004500
180097514755000*2438*25005000
2000102515255000*2438*25006500
2200110016006000*2438*25007500
2500117516756000*2438*25008000
3000122517257000*2438*250012000
4000130018008000*2438*250014000
5000137518759000*2438*250015000
60001425192512000*2438*250016000
70001500200012000*2438*250017000
80001575207512000*2438*250018000
Resistive Inductive Combined Load Bank Data Sheet
Load bankNominal voltageAccording to customer needs
Test frequency50Hz/60Hz
Load characterResistive inductiveload,to meet the needs of multiple parallel work
Power factor0.8
Load connectionCopper bar
Loading accuracy±3%
Three phase balanceInbalance:≤3%
Working modeContinuous work
Power supply3 phase 4 wire,380V/50Hz
Cooling modeForced air cooling,horizontal inlet,horizontal/vertical out let
Insulation classF
AccuracyThe sampling accuracy: 0.2; (Voltage:±0.5%,current:±0.5%,frequency:±0.1%,power:±1%,Cosφ:±1% )
Load expansionParallel expansion of multiple load containers
Load protectionShort circuit,over voltage,over current,high temperature,air volume,emergency stop protection
ResistiveloadMinimum step1kW
Load stepAccording to customer needs
Resistance tubeInsulation impedance of each resistor:DC2000V 10MΩ above,withstand voltage AC2000V 1 minute,resistance error of each resistance tube:±3%,Cold & hot state change:≤2%
Resistive materialSpecial alloy resistor
Inductive loadMinimum step1kvar
Load stepAccording to customer needs
InductorWithstand voltage AC3000V 1 minute,inductance error of each Inductor:±3%
MaterialAluminum reactor or copper reactor
OtherProtection levelIP56 when outdoor use, IP20 when indoor use
TransportLoad-bearing lifting holes/castors/forklift holes available
ColorWhite/blue/customized
StandardMeet international standard,ship standard and telecommunication standard
Ambient Temp.-20ºCto 50ºC
HumidityUp to 100%
AltitudeUp to 2500m
Atmospheric pressure86to 106kPa
Product Pictures(For Reference Only)
Company profile
Rata technology was established in 2013 and located at Luojiang High and New Technology Zone, Deyang City, China. The factory is nearby the high way and national road, with convenient shipment. It is about 5 hours from our factory to the nearest port.
There are professional technicians and skilled workers. During past 9 years, we are focus on development and production of kinds of load bank. By far, we have obtained 15 patents of load bank, ISO 9001 certificates and 8 computer software copyrights.
We are not only focus on products quality, but also on service. By far we obtained 5 stars contract performance capacity certificate and 7 stars after sales service certificate.
Rata Technology mainly produce and sale resistive load bank, resistive inductive combined load bank, resistive inductive and capacitive combined load bank, rack mounted load bank, DC load bank, electrical load bank and battery discharger.
Battery discharge test: Power battery, lead acid battery and fuel battery, BMS and battery protection equipment test, test of communication power supply and server power supply. Virtual load test of solar array and industrial motor. Test of DC charging pile, charging module and other electronic power devices.
Our load bank have been exported to Europe, Africa, , Asia and other regions and have good reputation.
You are welcome to visit our factory and look forward to cooperate with you.Certification