Load Bank for Generator Tesing UPS Testing DC Dummy Load Bank 28V
HomeHome > Products > DC Load Bank > Load Bank for Generator Tesing UPS Testing DC Dummy Load Bank 28V
Load Bank for Generator Tesing UPS Testing DC Dummy Load Bank 28V

Load Bank for Generator Tesing UPS Testing DC Dummy Load Bank 28V

Overview The DC load bank of our company adopts high reliability relay for switching,which is suitable for all voltage l
Basic Info.
Model NO. DC12-DC1000
Voltage DC28V
Rated Load 200A
Application UPS Testing Generator Testing
Customized Customized
Surface Treatment Chroming
Display Accuracy 0.2
Connection Mode Tn-C
Load Accuracy Plus or Minus 3%
Rated Voltage DC28V
Transport Package Carton/Wooden Case or Customized
Specification 600*680*1080
Trademark Rata
Origin China
HS Code 9030899090
Production Capacity 5000
Product Description

Load Bank for Generator Tesing UPS Testing DC Dummy Load Bank 28V-200A Loab Bank

Overview

The DC load bank of our company adopts high reliability relay for switching,which is suitable for all voltage levels.
DC load bank (electric discharge load) is suitable for testing the output power and carrying capacity of communication and AC equipment such as power supply,UPS equipment,AC voltage regulator,inverter and switching power supply.It is used for daily maintenance test,engineering acceptance and factory inspection test of various DC power supply.DC Load Bank Application and Features1. What is the load bank used for? 1.DC generator set,battery charging board,UPS charging board,photovoltaic combiner box and other DC power supply detection occasions.2.AC test server,UPS,generator set and other AC power supplies.3.Output power and load carrying capacity of communication AC equipment such as AC voltage stabilizer, inverter and switching power supply.4.Simulating resistive load can detect the performance of power supply under different loads.
2. Precautions1. The equipment power cord must be connected correctly.2. Before using the equipment, confirm that the equipment is in normal state, and the insulation to ground of 500V is not less than 1m Ω.3. It is forbidden to use the equipment under abnormal voltage.4. The equipment must be safely and reliably grounded before use.5. There shall be no obstacle 2 meters away from the air inlet and outlet of the equipment to avoid poor heat dissipation of the equipment and failure of the equipment to work normally.6. After high temperature protection, the equipment shall be reset to avoid secondary loading after load cooling7. During the test, pay attention to power safety to avoid electric shock.
Our Service
* 3 years quality warranty.* Supply professional consult and reply technical question in time.* Arrange fast and safe shipment as contract date.* More products' special function please contact the sale manager. You will be replied soon.Load Bank Design & Production As load bank manufacturer, we will make load bank design follow customers' load bank requirement and related standards,after the design accepted,load bank production will start and strictly based on the load bank design. Generally,it will takes about 3-5 weeks to produce the products.Load Bank Factory TestAll the load bank will be strictly test before delivery at the factory to make sure they are running well and with no problem.Load Bank Packing & Shipment For smaller load bank, carton or wooden case will be supplied to pack them,for larger load bank,generally will be packed with plastic film. If there is another requirement from the customers,no problem for us.Load Bank Installation The installation of the load bank shall mainly pay attention to the moisture-proof, dust-proof, insect proof, shockproof, anti-corrosion, safe and easy to use. Our company will fully consider the customer's use environment and requirements when designing and manufacturing the load bank based on related standards to ensure long-term safe and stable operation of the load bank. There are lifting holes,forklift holes and castors for choose to make sure the load bank easy to move and install.
DC Load Bank Specification
DC Load Bank Basic Specification
Electric current(A)Voltage(V)Size(mm,L*W*H)Weight(Kg)
100DC12-DC1000380*680*1020120
200600*680*1080250
500700*1000*1500400
1000800*1000*2000500
15001000*1000*2200650
20001000*1500*2200800

DC Load Bank Data Sheet

Rated voltage

According to customer needs

Load step

According to customer needs

Load accuracy

Each gear:±3%

Load accuracy

The whole machine is ±5%

Display accuracy

Grade 0.2

CONTROL POWER

External AC220V/50Hz

Connection mode

Load first DC power input-copper bar(DC positive and DC negative)

Load second DC power input-copper bar(DC positive and DC negative)

Control power input - Terminals(L+N)

Insulation class

F

Protection level

IP23

Cooling mode

Forced air cooling,side air inlet,side air outlet and upper air outlet

Noise

3 meters away from the equipment, less than or equal to 80 dB

Transport

Lifting, the top of the chassis with load-bearing rings, bottom with casters

Control mode

Local intelligent control

Function

I,V,kW real time display, electrical performance index detection, system electrical parameters monitoring

Color

Customized

Ambient temperature

-20ºCto 50ºC

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86to 106kPa

Product Pictures(For Reference Only)
Company profile
Rata technology was established in 2013 and located at Luojiang High and New Technology Zone, Deyang City, China. The factory is nearby the high way and national road, with convenient shipment. It is about 5 hours from our factory to the nearest port.
There are professional technicians and skilled workers. During past 9 years, we are focus on development and production of kinds of load bank. By far, we have obtained 15 patents of load bank, ISO 9001 certificates and 8 computer software copyrights.
We are not only focus on products quality, but also on service. By far we obtained 5 stars contract performance capacity certificate and 7 stars after sales service certificate.
Rata Technology mainly produce and sale resistive load bank, resistive inductive combined load bank, resistive inductive and capacitive combined load bank, rack mounted load bank, DC load bank, electrical load bank and battery discharger.
Battery discharge test: Power battery, lead acid battery and fuel battery, BMS and battery protection equipment test, test of communication power supply and server power supply. Virtual load test of solar array and industrial motor. Test of DC charging pile, charging module and other electronic power devices.
Our load bank have been exported to Europe, Africa, , Asia and other regions and have good reputation.
You are welcome to visit our factory and look forward to cooperate with you.Certification