500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank
HomeHome > Products > Load Bank > 500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank
500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank

500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank

Overview Package Size 191.00cm * 156.00cm * 143.00cm Package Gross Weight 1000.000kg 500kW AC Dummy Resistor Genset Gene
Overview
Basic Info.
Warranty 1 Year
Protection Level IP23
Voltage 440V
Rated Load 500kw
Application Load Test
Customized Customized
Surface Treatment Powder Coating
Weight 1000kg
Size 1910*1560*1430mm
Packing Wrapping Film+Wooden Pallet
Power Source Copper Bar + Terminal
Movement Forklift Holes
Design Outdoor with Canopy
Color Grey Ral 7035 or Others Color Number
Control Mode Manual or Automatic Control
Transport Package Wrapping Film+Wooden Pallet
Specification 500kW
Trademark Rata
Origin China
HS Code 9030899090
Production Capacity 15 Set/Month
Packaging & Delivery
Package Size 191.00cm * 156.00cm * 143.00cm Package Gross Weight 1000.000kg
Product Description

500kW AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank
> HS Code: 9030899090Product Photo

500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank

Product Parameters
Model No.RT500kWLBA
Load typeResistive
Nominal VoltageAC380V/440V/400V/Customized
Frequency50/60Hz
Capacity500kW
Power factor1.0
Control modeManual + PC control(automatic control): control the load through the data management software in the computer,realize all test functions,display,record and manage test data,generate various curves,charts and test reports and support printing. PC control system: Computer: I5 processing system laptop.Network cable: 50m category 6 network cable.Software control system.Communication interface: RJ45.Support printing.Table saved by EXCELL,curve saved by word. Software language: English
Application environmentOutdoor + canopy
Fan power source3 phase 4 wire(220V)
Load accuracy±3%
3Phase BalanceUnbalance: ≤3%
InsulationF
Power source connectionLoad power source connection: copper bar
Working power source connection: terminal
Time ratingContinuous design

Resistive load
Min.step: Nominal 1kw resolution or customized500kW steps: 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW*4or other choice like: 50kW,50kW,100kW*4 or 100kW*5 or others.
Electrical performance index of finned resistor:8020 Ni-Cr alloy finned resistorEach resistance element: insulation impedance DC2000V/10MΩ Withstand voltage AC 2000v for 1 minuteResistance error of each resistor: ±3%Long time work under 350ºCTemperature drift coefficient:±1.5%Work temperature is 1/3 of the design temperature.
Cooling systemCooling mode: Forced ventilation,horizontal air inlet/outlet
Airflow/Fan power and air volume shall be designed according to 2 times surplus coefficient of heat loss. Power supply mode: 3 phase AC power supply.Noise:≤ 65db (3M)The fan adopts axial flow fan, aviation aluminum fan blade, decentralized air supply design, sufficient air volume, low noise,high strength, corrosion resistance, durability and other advantages of the fan blade.
Load test functionsReal time display ofCurrentVoltageFrequencyPower Power factorElectrical performance indicatorsCurve and report output System electrical parameter monitoringAutomatic data acquisitionSampling accuracy: Voltage: ±0.5%; Current: ±0.5%; Frequency: ±0.1%; Power: ±1%; Power factor: ±1%
Load protection/ functionLow air volume: when the air volume of any fan is insufficient, it will automatically unload and alarm.High temperature: automatically unload and alarm when the load temperature exceeds the safety threshold. Fan interlock protection: the load cannot be loaded before the fan power switch is turned on.Short circuit/over current: the load circuit is equipped with a fuse to avoid damage to the equipment in case of load short circuit or excessive current. Emergency stop: manual one button forced unloading is available, and it cannot be loaded under emergency stop locking status.Fan phase sequence automatic transfer protection: when the control power line is not connected according to the correct phase sequence, the three-phase fan can also operate in the normal direction. Operational indicator: indicates whether the device can be put into load, and the indicator light on indicates that the device is in normal state and can be put into load. Fan operation indicator: indicates whether the fan of the device is running, and the corresponding indicator light for fan startup is on. Load switch: the control device is to switch on or off the load, and jog the switch to switch on the selected load.
ColorColor: RAL7035Material: Q235 cold rolled steel plate.
Transportation2 Forklift holes at the bottom middle of the load bank.
Dimension(L*W*H)1910mm*1560mm*1430mm
Weight1000kg
PackingWrapped film + wooden pallet
Main partsContactor/Circuit breaker:ABB/Schneider brand
Work Environment
Temperature-20ºC to 50ºC
Humidityup to 100%
Altitudeup to 2500m
Atmospheric pressure86 to 106kPa
Others
CertificatesCE/ISO9001/ISO14001/ISO45001/SGS
Factory testWe will do it and make report
Operation manualWe will supply
Lead time30-35 days if order less than 5 sets
HS code9030899090
Detailed Photos

500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank

Packaging & Shipping

500kW resistive load bank packed with film and wooden pallet.

500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank

Company Profile

Rata was established in 2013 and located at Luojiang High and New Technology Zone, Deyang City, China. The factory is nearby the high way and national road, with convenient shipment. It is about 5 hours from our factory to the nearest port. There are professional technicians and skilled workers. During past 10 years, we are focus on development and production of kinds of load bank. By far, we have obtained 25 patents of load bank, ISO 9001/14001/45001 certificates,SGS factory inspection,CE certificate and 8 computer software copyrights. We are not only focus on products quality, but also on service. By far we obtained 5 stars contract performance capacity certificate and 7 stars after sales service certificate. Rata Technology mainly produce and sale resistive load bank, resistive reactive load

bank, rack mounted load bank, DC load bank, electrical load bank and battery discharger. Our load bank have been exported to America,Europe, Africa, Asia and other regions and have good reputation. You are welcome to visit our factory and look forward to cooperate with you.

500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank

Certifications

500kw Outdoor Design AC Dummy Resistor Genset Generator Testing Resistive Automatic Control Load Bank


FAQ1- Are you manufacturer?
Yes, we are manufacturer of load bank for 10 years,we have rich experience of load bank design and production. We've already produced the load bank from 2kW to 5000kW(single load bank),115kVA to 5000kVA(single load bank).
2- What is the delivery time?
30-35 days generally. if your quantity is big,it need more days.
3- What certificates you have?
ISO9001:2015,ISO14001:2015,ISO45001:2018,CE,SGS and 25 patents for load bank.
4- Do you accpect customized logo,color?
Yes.
5- What is the nerest port?
Shanghai port,China. Generally we can delivery the goods to any China port.
6- What price you can quote?
EXW,FOB,CIF,DDU
7- What is the payment term?
T/T